2026 Ren Data Center Voltage Ride Through Hosting Capacity

Pengyu Ren, Wei Sun

2026endata centershosting capacityvoltage ride-throughpower systemsgrid stabilityuninterruptible power supply

Abstract

Language:

Large data centers are emerging as concentrated, power-electronic grid loads whose abrupt disconnection or transfer to on-site backup supply during voltage disturbances can remove large demand from the power system, and may create a system-level stability problem. Their interconnection feasibility therefore depends not only on steady-state thermal and voltage limits, but also on whether internal power-conditioning systems can maintain IT service while limiting customer-initiated load reduction. This paper presents a voltage ride-through (VRT)-aware data center and grid co-planning framework that couples transmission-level fault simulation with an internal data center ride-through model. Python-based dynamic simulations generate point-of-interconnection (POI) voltage trajectories under selected network faults, and the resulting waveforms drive an internal model incorporating IT and cooling-load dynamics, DC-link, Uninterruptible Power Supply (UPS) response, and converter apparent power limits. The IEEE 118-bus case study shows that internal VRT capability can become a binding interconnection constraint: steady-state planning alone can overestimate feasible data center capacity, whereas increased UPS converter headroom progressively restores hosting capacity. Under the reduced-order response models studied, the grid-forming mode provides greater ride-through margin than the current-limited grid-following mode under the same network fault conditions. The results further show that VRT constraints can materially change both the total hosting capacity of data centers and its spatial allocation across candidate interconnection buses.

Download

Cite This Work

@article{4eec3046-291f-4c2b-985d-79fdfe50a397,
  title={2026 Ren Data Center Voltage Ride Through Hosting Capacity},
  author={Pengyu Ren and Wei Sun},
  year={2026},
  language={en}
}
TY  - JOUR
TI  - 2026 Ren Data Center Voltage Ride Through Hosting Capacity
AU  - Pengyu Ren
AU  - Wei Sun
PY  - 2026
LA  - en
ER  -

Similar Items

Coordinated computing energy optimization of data center micro 2027 Applied

Changming Chen, Aokang Pang

With the rapid advancement of cloud computing, big data and artificial intelligence technologies, data center microgrids (DCMGs) have become crucial i

2026enPDF

Bridging the grid-thermal-computational nexus via physics-informed hierarchical multi-agent reinforcement learning for data center co-optimization

Zekai Jin, Yue Zhou

Driven by the rapid growth of cloud computing and artificial intelligence, data centers (DCs) are becoming large, flexible loads that increasingly aff

2027enPDF

Unlocking the potential benefits of intertemporal resources via 2027 Applie

Xiaobing Zhang, Zhifang Yang

With the large-scale integration of clean energy resources — including hydropower, wind, and solar power — together with battery energy storage system

2026enPDF

Metal Casting Processes

Unknown, Unknown

This chapter discusses metal casting processes, highlighting the diversity and common characteristics among them. The objective is to elucidate the fu

2023enPDF

The Nature of Solid Iron and Its Grain Structure

Unknown, Unknown

This study focuses on the fundamental characteristics of solid iron, which is predominantly composed of iron atoms and provides a basis for understand

2023enPDF

842063941 SX configuration

2026enPDF